SIZE OF WWTP 300 m3/day (79 250 GPD)
END USER Public utility provider, Gyulai Közüzemi Nonprofit Kft.
CUSTOMER Pure-Aqua Kft.
START OF OPERATION October, 2015

Issue

The client was not satisfied with the existing belt-filter press because of high repair and maintenance costs, therefore they decided to change it during the general reconstruction of WWTP. The client was looking for sludge dewatering solution with low power consumption as well as small footprint to be installed in place of the existing filter press.

Solution

After the detailed analysis and comparison with other manufacturers, the client chose our dehydrator MDQ-201. During the design stage, EKOTON specialists actively assisted in the development of sludge dewatering scheme.

Results

Type of sludgeMixture of primary sludge and
waste activated sludge
Unit Sludge Supply0.5-1.3 m3/h (2.2-5.7 GPM)
16-18 kg DS/h (35-40 lb DS/h)
Feed Sludge DS Concentration2 %
Cake DS Concentration18 %
Operation Time5-6 h/d
Average Polymer Dose3.5-4 g/kg DS (7-8 lb/ton DS)
Unit Daily Power Consumption4-5 kW*h